Development of large displacement transducers to improve the efficiency of liquid level gauges
DOI:
https://doi.org/10.21303/2461-4262.2026.004405Keywords:
inductive transducer, sectional stepped solenoid, differential transformer, liquid level measurement systemAbstract
The object of research is the measurement of liquid level in industrial technological systems, particularly under operating conditions of petrochemical production where large displacement ranges, measurement linearity, and compact sensing elements are required. The aim of research is to develop and experimentally evaluate a large-displacement inductive transducer based on a differential transformer with a stepped sectional secondary winding arrangement for application in liquid-level measurement systems. The proposed transducer was investigated using a prototype with a coil diameter of 46 mm and a working coil length of 500 mm, while the movable ferromagnetic core had a length of 20 mm and a diameter of 20 mm. The prototype operated at an excitation frequency of 50 Hz and contained five measuring winding sections.
A mathematical model was developed to determine the relationship between core displacement and output voltage and to evaluate the sensitivity of the transducer. Experimental measurements were compared with the calculated characteristics. The maximum deviation between the calculated and experimental characteristics did not exceed 12%, while the experimentally determined nonlinearity was below 3.5% over the operating stroke. The movable core length represented approximately 4% of the working coil length, demonstrating the possibility of obtaining a large measurement range with a compact moving element. The obtained results demonstrate that the stepped differential winding configuration provides a linear displacement-output relationship while increasing the effective sensitivity and reducing the required dimensions of the movable ferromagnetic core. These characteristics support the application of the developed transducer in industrial liquid-level measurement and automated process-control systems.
Downloads
References
Ripka, P., Tipek, A. (Eds.) (2007). Modern Sensors Handbook. https://doi.org/10.1002/9780470612231
Fraden, J. (2016). Handbook of Modern Sensors. Springer International Publishing. https://doi.org/10.1007/978-3-319-19303-8
Webster, J. G., Eren, H. (Eds.) (2017). Measurement, Instrumentation, and Sensors Handbook. CRC Press. https://doi.org/10.1201/b15664
Liptak, B. G. (Ed.) (1995). Instrument Engineers’ Handbook, (Volume 1). CRC Press. https://doi.org/10.1201/b12404
Pallàs-Areny, R., Webster, J. G. (2012). Sensors and Signal Conditioning. Wiley. Available at: https://content.e-bookshelf.de/media/reading/L-805983-159098eec0.pdf
Peng, K., Wang, Z., Fan, X., Yu, Z., Wang, H. (2025). Design and optimization of large-range absolute linear displacement sensors based on splicing technology. Measurement, 242, 115943. https://doi.org/10.1016/j.measurement.2024.115943
Kukkadapu, K. A., Van Haevermaet, H., Beaumont, W., van Remortel, N. (2026). Design and Optimisation of Linear Variable Differential Transformers and Voice Coil Actuators Using Finite Element Analysis: A Methodical Approach to Enhance Sensor Response and Actuation Force. Sensors, 26 (8), 2564. https://doi.org/10.3390/s26082564
He, Q., Fan, S., Chen, N., Tan, R., Chen, F., Fan, D. (2021). Analysis of Inductive Displacement Sensors with Large Range and Nanoscale Resolution. Applied Sciences, 11 (21), 10134. https://doi.org/10.3390/app112110134
Berger, M., Zygmanowski, A., Zimmermann, S. (2021). Differential Inductive Sensing System for Truly Contactless Measuring of Liquids′ Electromagnetic Properties in Tubing. Sensors, 21 (16), 5535. https://doi.org/10.3390/s21165535
Lu, X., Tian, G., Wang, Z., Li, W., Yang, D., Li, H., Wang, Y. et al. (2022). Research on the Time Drift Stability of Differential Inductive Displacement Sensors with Frequency Output. Sensors, 22 (16), 6234. https://doi.org/10.3390/s22166234
Mociran, B., Gliga, M. (2023). Optimization of an Inductive Displacement Transducer. Sensors, 23 (19), 8152. https://doi.org/10.3390/s23198152
Pop, S. S., Flutur, A.-F., Fodor, A. (2025). Design and Implementation of an Inductive Proximity Sensor with Embedded Systems. Sensors, 25 (19), 6258. https://doi.org/10.3390/s25196258
Gao, L., Xu, Q., Miao, Y., Zhang, W., Wang, C., Li, M., Tang, S. (2025). A Novel Inductive Displacement Sensor Based on Dual-Excitation and Single-Sensing Coils for Core Displacement Measurement. Sensors, 25 (9), 2827. https://doi.org/10.3390/s25092827
Yan, Q., Xiao, Y., Zheng, L., Pan, C., Ni, Q., Wang, T. et al. (2025). Design and experimental verification of the quench detection system for the CFETR central solenoid model coil. Superconductivity, 16, 100212. https://doi.org/10.1016/j.supcon.2025.100212
Downloads
Published
Versions
- 2026-09-30 (Version of Record 1.0)
Data Availability Statement
Data cannot be made available for reasons disclosed in the data availability statement.
Funding Statement
The research was performed without financial support.
Issue
Section
License
Copyright (c) 2026 Javanshir Mammadov (Author); Bahruz Gurban Amiraslanov (Author); Anahanim Sahib Mutallimova (Author); Gulnara Shahin Isgandarova (Author); Rukhsara Zahid Novruzova (Author)

This work is licensed under a Creative Commons Attribution 4.0 International License.
Our journal abides by the Creative Commons CC BY copyright rights and permissions for open access journals.
Authors, who are published in this journal, agree to the following conditions:
1. The authors reserve the right to authorship of the work and pass the first publication right of this work to the journal under the terms of a Creative Commons CC BY, which allows others to freely distribute the published research with the obligatory reference to the authors of the original work and the first publication of the work in this journal.
2. The authors have the right to conclude separate supplement agreements that relate to non-exclusive work distribution in the form in which it has been published by the journal (for example, to upload the work to the online storage of the journal or publish it as part of a monograph), provided that the reference to the first publication of the work in this journal is included.